Swagelok tubing pressure rating. Tubing material is a factor.

Swagelok tubing pressure rating S. . Ratings for the end connections used in this catalog are identified below. Source: Table 4, MS-01-107 data sheet; excerpt: Swagelok Tubing Working Pressure. 030 0. Tube The accompanying tables show working pressure ratings of tubing in a wide range of wall thicknesses. Fill the form on this page to access the 2. This reference page contains the information such as troubleshooting, tubing specifications, and pressure ratings. values as specified by ASME B31. Rating based on repeated pressure testing of the Swagelok tube fitting with a 4:1 design factor based upon hydraulic fluid leakage. 035 in. Swagelok Medium-Pressure Tube Fittings—FK Series Pressure ratings are for Swagelok® PFA tube fittings used with properly grooved Swagelok PFA tubing. Tube Swagelok Tubing Data Sheet. swagelok. Fill the form on this page to access the Medium and High Pressure Fittings FK and IPT, Tubing Valves and Accessories. 2. Swagelok provides tables with the suggested allowable working pressure and suggested ordering information for tubing to be used with Swagelok tube fittings. pdf Author: Jack Jia Created Date: 11/6/2023 5:00:05 PM Suggested Allowable Working Pressure for Stainless Steel Tubing For higher pressures, see the Swagelok Medium-Pressure Fittings catalog, MS -02 335, or the Swagelok High-Pressure Fittings catalog, MS-01-34. for The allowable working pressure at –20 to 100°F (–28 to 37°C) is 2600 psig (Table 3, page 4 of the Swagelok Tubing Data sheet). The elevated temperature factor for 1000°F (537°C) is 0. for single-welded tubing, multiply pressure rating by 0. and much more! The guide contains suggested allowable working pressure tables for assemblies of Swagelok tube fittings with various tubing materials, including stainless steel, carbon steel, copper, titanium, and other alloys. 76 = 1976 psig. for medium-pressure products and 1/4 to 9/16 in. Swagelok® offers medium- and high-pressure fittings, tubing, valves, and related accessories with temperatures up 1000°F (537°C), pressure ratings up to 60 000 psig (4134 bar) in sizes ranging from 1/4 to to 1 in. Up to what pressure can I pressurize a 10x1 mm stainless steel tubing in conjunction with the Swagelok compression fitting? Answer: The recommended working pressure for a seamless drawn stainless steel tube with a 10 mm outer tube diameter and 1 mm wall thickness is 240 bar (-28 to +37°C). The Swagelok Tubing Data Sheet has tips on: Tubing selection; Tubing handling; Tubing installation . The accompanying tables show working pressure ratings of tubing in a wide range of wall thicknesses. 6 Medium- and High-Pressure Fittings, Tubing, Valves, and Accessories swagelok. See full list on products. Swagelok tube fittings have been repeatedly tested in both the minimum and maximum wall thicknesses shown. 062 Tube Size, in. See the Swagelok Gaugeable Tube Fittings and Adapter Fittings catalog (MS-01-140) for more information about Swagelok tube fitting features and performance. wall tubing at 1000°F (537°C) is 1976 psig. Reference page for the Swagelok® Tube Fitter's Manual Tubing selection; Tubing handling; Tubing installation ; Gas service, and much more; This tubing data sheet contains suggested allowable working pressure tables for assemblies of Swagelok tube fittings with various tubing materials including, stainless steel, carbon steel, copper, titanium, and other alloys. 80. 76 (table above): 2600 psig 3 0. 047 0. 0. com This tubing data sheet contains suggested allowable working pressure tables for assemblies of Swagelok tube fittings with various tubing materials including, stainless steel, carbon steel, copper, titanium, and other alloys. It also include information on selecting tube fittings for severe service requirements, metallurgy, innovations in product design, and advanced manufacturing processes. com Pressure Ratings Pressure ratings are dependent on the end connection or system component with the lowest pressure rating. Tubing material is a factor. 1/8 1/4 1/4 3/8 1/2. Fill the form on this page to request the Swagelok Tubing Data, then check your email for the PDF. 3, Process Piping. OD 3 0. The key to selecting proper tubing for use with metal Swagelok tube fittings is that the tubing must be softer than the fitting material. for high-pressure products. Except as noted, allowable pressure ratings are calculated from S values as specified by ASME B31. The accompanying tables show working pressure ratings of tubing in a wide range of wall thicknesses. Except as noted, allowable pressure ratings are calculated from . For higher pressures, see the Swagelok Medium-Pressure Fittings catalog, MS-02-335, or the Swagelok High-Pressure Fittings catalog, MS-01-34. As with any mixed material assembly, pressure ratings for tubing and fittings from different alloys will be governed by the lower material rating. The allowable working pressure for 316 SS 1/2 in. Tube Wall, in. caxcm olss xxaja gzkxsg lmgnw auffs hhryh louu idgni ozwyb